Skip to main content |
Keyboard shortcuts for the dpp.cz website |
Skip content, go to navigation |
Skip to search |
Transit restrictions |
Contacts |
Fares |
My profile |
|
|
Infoline: 296 19 18 17, We speak english
For a barrier-free transportation of immobile persons, passengers with prams, and handicapped persons, a staircase ramp can be used, integrated in a fixed staircase and connecting the entrance space with a metro platform. The entrance is provided with a barrier-free access.
For the current status of the barrier-free access facility, click here.

The ramp route is separated by a glass wall from the fixed staircase and step-on areas are provided with entrance preventing barriers, if the ramp moves or is outside of the platform space. The ramp space is provided with an automated barrier preventing passengers to leave the space outside of the step-on area.
Instructions for use, available at both upper and lower station and the ramp shield, are to be followed during the ramp operation.
CAUTION! The operation button controlling a ramp recall or a travel must be pressed and held down during the entire period of the ramp travel, otherwise the ramp would stop.
Selected ramp technical specifications are provided in the following table.
At both entrances, the ramp is provided with symbol icons and the access at the metro entrance space and platforms is indicated on information panels.
Staircase ramp (P 341)
Horní nástup plošiny v úrovni vestibulu. Na snímku je plošina v horní stanici, připravená na nástup cestujícího a následně k jeho přepravě na nástupiště metra.
Dolní nástup plošiny v úrovni nástupiště. Na snímku je plošina v horní stanici. Pro přepravu cestujícího je nezbytné plošinu přivolat stiskem tlačítka, které je nutné držet ve stisknuté poloze po celou dobu jízdy, dokud se plošina automaticky nezastaví v prostoru dolního nástupu.
|
Selected ramp technical specifications |
||
|
1. |
Ramp type |
self-service, for personal transportation |
|
2. |
Load capacity (kg) |
max. 250, 2 persons |
|
3. |
Travel height (m) |
4,99 |
|
4. |
Travel speed (m/s) |
0,15 |
|
5. |
Ramp transportation area |
W x L 900 mm x 1400 mm. |
|
6. |
Ramp step-on and space protections |
Step-ons are provided with automated entrance-preventing barriers when the ramp travels or is outside of the step-on space. The ramp space is provided with an automated barrier preventing passengers to leave the space outside of the step-on area. |
|
7. |
Floor (level) connected by the ramp |
entrance space at the street level with the platform level |
|
8. |
Stations # |
2 |
|
9. |
Communication from the ramp in emergency |
Pressing the emergency button activates an emergency indicator device at the permanent operator's room. |
|
10. |
Control devices on platforms and a ramp panel |
are not provided with Braille descriptions. CAUTION! A person transported must press and hold down the operation button controlling a ramp recall or a travel during the entire period of the ramp travel, otherwise the ramp would stop. |
|
11. |
Indication of the ramp arrival to stations |
N/A |
|
12. |
Size of free area in front of ramp step-on points |
upper platform : not limited |
|
lower platform : not limited. |
||
|
13. |
Closed Circuit TV monitoring |
on platforms and along the entire ramp route. |