The barrier-free access at Metro Muzeum Station is provided by lifts from C Line and A Line platforms
For the current status of the barrier-free access facility, click here.
For a barrier-free transportation of immobile persons, passengers with prams, and handicapped persons, a pair of personal lifts can be used, entrances of which are situated in the area between Vinohradská Street and the National Museum building. The lifts connect the street level with the level of A Line platforms.
Caution: The lifts do not make possible an access or a line change on C Line platforms.
For a barrier-free transportation of immobile persons, passengers with prams, and handicapped persons, a personal lift can be used, an entrance to which is situated in the park between Washington Street and Wilson Street, in the direction towards Metro Hlavní Nádraží Station.
Caution: The lift does not make possible an access or a line change on A Line platforms.
A change between metro lines is only possible via a ground surface route. For example, to change between C and A lines, a lift from C Line to the ground level is to be used and then, the route follows land surface communications and leads to A Line lifts.
Selected lift technical specifications are provided in the following table.
At both entrances, the lifts are provided with symbol icons and the access to the lifts at the metro platforms is indicated on information panels.
The lift from A Line platform to the area between Vinohradská Street and the National Museum building (OsV 289, 290)
Vstup z ulice
vstup z nástupiště
|
Selected technical specifications of A Line lift (identical to both lifts) |
||
|
1. |
Lift type |
self-service, for personal transportation |
|
2. |
Load capacity (kg) |
1200 |
|
3. |
Travel height (m) |
35,3 |
|
4. |
Travel speed (m/s) |
1,6 |
|
5. |
Lift entrance door width and design |
1200 mm, automated horizontal shift door |
|
6. |
Lift cabin size and design |
W x D 1300 mm x 2100 mm, through-traffic cabin. |
|
7. |
Floor (level) connected by the lift |
street level with A Line platform level |
|
8. |
Stations # |
2 |
|
9. |
Communication from the lift cabin in emergency |
pressing the emergency button activates a two-way communication device, connecting to the permanent operator's room. |
|
10. |
Control devices on platforms and in the lift cabin |
are provided with Braille descriptions. |
|
11. |
Indication of the lift arrival to stations |
sound signal of 35-55 dB intensity |
|
12. |
Size of free area in front of lift step-in points |
upper platform : not limited |
|
lower platform : not limited. |
||
|
13. |
Closed Circuit TV monitoring |
is provided on platforms, as well as in the lift cabin. |
The lift from C Line platform to the park between Washington Street and Wilson Street - in the Metro Hlavní Nádraží Station direction (OsV 025)
Vstup z parku
Vstup z nástupiště
|
C Line lift selected technical specifications |
||
|
1. |
Lift type |
self-service, for personal transportation |
|
2. |
Load capacity (kg) |
630 |
|
3. |
Travel height (m) |
9,02 |
|
4. |
Travel speed (m/s) |
0,65 |
|
5. |
Lift entrance door width and design |
800 mm, automated horizontal shift door |
|
6. |
Lift cabin size and design |
W x D 1100 mm x 1400 mm, not through-traffic cabin |
|
7. |
Floor (level) connected by the lift |
street level with C Line platform level |
|
8. |
Stations # |
2 |
|
9. |
Communication from the lift cabin in emergency |
Pressing the emergency button activates a two-way communication device, connecting to the permanent operator's room. |
|
10. |
Control devices on platforms and in the lift cabin |
Lift cabin control elements are provided with Braille descriptions. |
|
11. |
Indication of the lift arrival to stations |
sound signal of 35-55 dB intensity |
|
12. |
Size of free area in front of lift step-in points |
upper platform : not limited |
|
lower platform : An access from C Line platform in the Háje direction, through a corridor (W x L 1350 mm x cca 7 m. The platform not limited |
||
|
13. |
Closed Circuit TV monitoring |
Is provided on platforms, however, not in the lift cabin. |